General Specifications  
Cable Type   Stranded loose tube
Construction Type   Non-armored
Subunit Type   Gel-free
   
Construction Materials  
Fiber Type Solution   LazrSPEED® 150, 50 μm multimode fiber (OM2+)
Jacket Material   PE
Total Fiber Count   24
Fiber Type   LazrSPEED® 150, 50 μm multimode fiber (OM2+)
Fiber Type, quantity   24
Fibers per Subunit, quantity   12
Jacket Color   Black
Jacket UV Resistance   UV stabilized
   
Dimensions  
Buffer Tube/Subunit Diameter   2.50 mm   |   0.10 in
Cable Weight   66.0 kg/km   |   44.0 lb/kft
Diameter Over Jacket   10.20 mm   |   0.40 in
Filler, quantity   3
Subunit, quantity   2
   
Physical Specifications  
Minimum Bend Radius, loaded   15.3 cm   |   6.0 in
Minimum Bend Radius, unloaded   10.2 cm   |   4.0 in
Tensile Load, long term, maximum   180 lbf   |   800 N
Tensile Load, short term, maximum   2700 N   |   607 lbf
Vertical Rise, maximum   1247.0 m   |   4091.2 ft
   
Environmental Specifications  
Environmental Space   Aerial, lashed   |   Buried
Installation Temperature   -30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature   -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature   -40 °C to +75 °C (-40 °F to +167 °F)
   
Mechanical Test Specifications  
Compression   125 lb/in   |   22 N/mm
Compression Test Method   FOTP-41   |   IEC 60794-1 E3
Flex   35 cycles
Flex Test Method   FOTP-104   |   IEC 60794-1 E6
Impact   2.17 ft lb   |   2.94 N-m
Impact Test Method   FOTP-25   |   IEC 60794-1 E4
Strain   See long and short term tensile loads
Strain Test Method   FOTP-33   |   IEC 60794-1 E1
Twist   10 cycles
Twist Test Method   FOTP-85   |   IEC 60794-1 E7
Water Penentration   24 h
Water Penentration Test Method   FOTP-82   |   IEC 60794-1 F5
   
Environmental Test Specifications  
Cable Freeze   -2 °C   |   28 °F
Cable Freeze Test Method   FOTP-98   |   IEC 60794-1 F15
Heat Age   -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method   IEC 60794-1 F9
Low High Bend   -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method   FOTP-37   |   IEC 60794-1 E11
Temperature Cycle   -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method   FOTP-3   |   IEC 60794-1 F1
   
Qualification Specifications  
Cable Qualification Standards   ANSI/ICEA S-87-640   |   EN 187105   |   Telcordia GR-20
Regulatory Compliance/Certifications
Agency Classification
RoHS 2011/65/EU Compliant
ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system
Logo        
Included Parts
CS-5M-LT   (Product Component—not orderable)
LazrSPEED® 150 OM2+ Bend-Insensitive Multimode Fiber
Optical Specifications, Wavelength Specific  
Standards Compliance   TIA-492AAAB (OM2+)
Attenuation, maximum   1.00 dB/km @ 1300 nm
3.00 dB/km @ 850 nm
Index of Refraction   1.479 @ 1300 nm
1.483 @ 850 nm
1 Gbps Ethernet Distance   600 m @ 1300 nm
800 m @ 850 nm
10 Gbps Ethernet Distance   150 m @ 850 nm
492 ft @ 850 nm
Bandwidth, Laser, minimum   500 MHz-km @ 1300 nm
950 MHz-km @ 850 nm
Bandwidth, OFL, minimum   500 MHz-km @ 1300 nm
700 MHz-km @ 850 nm
Differential Mode Delay   0.70 ps/m @ 850 nm
0.88 ps/m @ 1300 nm
Backscatter Coefficient   -75.7 dB @ 1300 nm
-68.0 dB @ 850 nm
   
Physical Specifications  
Cladding Diameter   125.0 µm
Cladding Diameter Tolerance   ±1.0 µm
Cladding Non-Circularity, maximum   1.0 %
Coating Diameter (Colored)   254 µm
Coating Diameter (Uncolored)   245 µm
Coating Diameter Tolerance (Colored)   ±7 µm
Coating Diameter Tolerance (Uncolored)   ±10 µm
Coating/Cladding Concentricity Error, maximum   6 µm
Core Diameter   50.0 µm
Core Diameter Tolerance   ±2.5 µm
Core/Clad Offset, maximum   1.5 µm
   
Optical Specifications, General  
Numerical Aperture   0.200
Numerical Aperture Tolerance   ±0.015
Point Defects, maximum   0.15 dB
Zero Dispersion Slope, maximum   0.105 ps/[km-nm-nm]
Zero Dispersion Wavelength, maximum   1316 nm
Zero Dispersion Wavelength, minimum   1297 nm
   
Mechanical Specifications  
Coating Strip Force, maximum   8.9 N   |   2.0 lbf
Coating Strip Force, minimum   1.3 N   |   0.3 lbf
Dynamic Fatigue Parameter, minimum   18
Macrobending, 15 mm mandrel, 2 turns   0.20 dB @ 850 nm
0.50 dB @ 1300 nm
Macrobending, 30 mm mandrel, 2 turns   0.10 dB @ 850 nm
0.30 dB @ 1300 nm
Macrobending, 75 mm mandrel, 100 turns   0.50 dB @ 850 nm
0.50 dB @ 1300 nm
Proof Test   0.69 N/mm²   |   100.00 psi
   
Environmental Specifications  
Heat Aging, maximum   0.20 dB @ 85 °C
Temperature Dependence, maximum 0.10 dB
Temperature Humidity Cycling, maximum 0.20 dB
Water Immersion, maximum   0.20 dB @ 23 °C