DL DVU 1-4 filter s diplex filter

DL DVU 1-4 filter s diplex filter

DVU 1-4 filter s diplex filter

4,64 €

5,57 € s DPH

Skladové číslo: 1-1993

Dostupnosť: Nie je skladom

Výrobca: DKT

Product information DVU products are designed to minimize noise from existing local installations when upgraded for data services. The datafilters are built to comply with CENELEC standards. DKTCOMEGA DVU 4, DVU 7 are developed to ease the upgrade of local installations for data services with a built-in return path filter minimizing noise coming from the existing installation. Build to comply with CENELEC standards.

Type DVU 1-4 DVU 4 DVU 7
Item no. 41138 41134 41135
Version Diplex Standard Standard
DATA
Frequency range forward 118-1000 MHz 5-1000 MHz 5-1000 MHz
Frequency range reverse 5-65 MHz 5-1000 MHz 5-1000 MHz
Insertion loss forward 4.0 (± 0.8) dB 3.5 dB 7.0 dB
Insertion loss reverse 0.6 (± 0.6) dB 3.5 dB 7.0 dB
Isolation DATA-TV/R (5-65 MHz) > 50 dB > 65 dB > 55 dB
Isolation DATA-TV/R (88-1000 MHz) > 20 dB > 20 dB > 18 dB
Return loss* Cat. B Cat. B Cat. B
TV/R
Frequency range 87.5-1000 MHz 87.5-1000 MHz 87.5-1000 MHz
Insertion loss 4.0 (± 0.8) dB 3.5 dB 2.0 dB
Return loss* Cat. B Cat. B Cat. B
General
Input return loss* (5-1000 MHz) Cat. B Cat. B Cat. B
Connectors F-female F-female F-female
Screeningeffectiveness (5-30 MHz) > 90 dB
Screeningeffectiveness (30-300 MHz) > 85 dB
Screeningeffectiveness (300-470 MHz) > 80 dB
Screeningeffectiveness (470-1000 MHz) > 75 dB
Operating temperature 0-55 oC
Dimensions (H x W x D) 19 x 66.5 x 50 mm
Weight loose(1 pcs.) 110 g
Weight innercolli (10 pcs.) 1.1 kg
Weight mastercolli (100 pcs.) 11.1 kg 23.3 kg 23.3 kg

 

*Return loss according to CENELEC EN-50083-4:

Cat. A: 5-40 MHz ≥ 22 dB, 40-1750 MHz min. 14 dB ÷ 1.5/oct.

Cat. B: 5-40 MHz ≥ 18 dB, 40-1750 MHz min. 10 dB ÷ 1.5/oct.

Cat. C: 5-40 MHz ≥ 14 dB, 40-1750 MHz min. 10 dB ÷ 1.5/oct.

Cat. D: 5-1750 MHz ≥ 10 dB 

 

Screening effectiveness/RFI= Class A
 

According to CENELEC EN-50083-2 Class A requirements for the electromagnetic compatability of equipment:

5-30 MHz
30-300 MHz
300-470 MHz
470-950 MHz
950-1000 MHz
 >85 dB
 >85 dB
 >80 dB
 >75 dB
 >55 dB